Lossy Data


εDC = relative dielectric permittivity at low frequency
ε = relative dielectric permittivity at infinite frequency
τ (ns) = time constant of relaxation at infinite temperature
E (eV) = activation energy
α = distribution of the relaxation parameter
μr = real part of relative magnetic permeability
ρDC (kΩm) = DC resistivity
UCI = Upper Confidence Intervals
LCI = Lower Confidence Intervals

Sample ID GHKwMI
(click to see data)
PuNeHID
(click to see data)
JSC1
(click to see data)
HemOr
(click to see data)
GHSChp
(click to see data)
Dominant Minerology Grey Hematite
(sample characterization)
Plagioclase
(sample characterization)
Plagioclase
(sample characterization)
Hematite
(sample characterization)
Grey Hematite? and Magnetite?
  95.5% LCI 9.73 8.12      
εDC Best Fit 9.86 8.23 7.24    
  95.5% UCI 9.92 8.36      
  95.5% LCI 2.80 2.58      
ε Best Fit 2.91 2.69 3.07    
  95.5% UCI 3.12 2.78      
  95.5% LCI 1.64×10-4 6.40×10-3      
τ(ns) Best Fit 2.56×10-4 2.69×10-2 0.8086    
  95.5% UCI 3.17×10-4 8.63×10-2      
  95.5% LCI 0.139 0.107      
E (eV) Best Fit 0.145 0.132 0.167    
  95.5% UCI 0.151 0.162      
  95.5% LCI 0.858 0.276      
α Best Fit 0.861 0.285 0.120    
  95.5% UCI 0.884 0.296      
ρDC (kΩm) >50 >50 >50 >50 >50
μr 1.00+0.03 1.00+0.03 1.00+0.03 1.00+0.03 1.00+0.03